Small Laminar Flow Hood with HEPA Filter H14
Small Laminar Flow Hood with HEPA Filter H14
Small Laminar Flow Hood with HEPA Filter H14
Small Laminar Flow Hood with HEPA Filter H14
Small Laminar Flow Hood with HEPA Filter H14
Small Laminar Flow Hood with HEPA Filter H14

PureFlow 600 – Laminar flow hood (vertical / horizontal)

PureFlow 600: the compact laminar flow hood that makes all the difference.

Create an ultra-clean air zone for your procedures (agar plates, transfers, liquid cultures) in just a few minutes and say goodbye to most contamination. Place it on a clean table; it can be used horizontally or vertically, and is even ideal for pressurizing a small room: a reliable, durable tool designed to help you work with peace of mind.

€479.90 Sale
- +

PureFlow 600 Laminar Flow Hood – HEPA H14 – Mycosphere

Choose your size

PureFlow 600 (575 × 575 × 320 mm)

  • Perfect for tabletop use, compact units
  • Agar, plate transfers, liquid culture
  • Minimal space requirements

You are on this page.

PureFlow 1200 (1175 × 575 × 320 mm)

  • Spacious work area (accommodates 2 people)
  • Perfect for handling “large volumes”
  • Also very useful for pressurizing rooms

→ See the PureFlow 1200

The PureFlow 600 is a laminar flow hood designed to create a zone of filtered air above your work surface. Its purpose is simple: to significantly reduce contamination during sensitive procedures (agar, transfers, liquid cultures, grains, clones, etc.).

Objective: to work in a filtered, uniform airflow in order to minimize the entry of spores, dust, and particles into your open containers.

Understanding laminar flow

What is a laminar flow hood?

A laminar flow hood draws in air, passes it through a pre-filter and then a HEPA H14 filter, and returns clean, uniform air in a steady stream. This allows you to work “within” a curtain of filtered air that limits the entry of spores, dust, and particles into your open containers.

The H14 HEPA filter captures ≥ 99.995% of particles ≥ 0.3 µm, including fine dust, spores, and biological microparticles.

Good to know: A fume hood does not replace proper safety practices. For best results, work in a clean, draft-free area and disinfect your work surface (according to your protocols).

Who is the PureFlow 600 designed for?

✔ Motivated beginners and advanced hobbyists
✔ Producers looking for a compact and reliable unit
✔ Agar, transfers, liquid cultures, inoculations
✔ Benchtop units / limited space

Need help choosing?
Our team offers free advice based on your specific needs (agar, liquid culture, volume, facility).
→ contact@lamycosphere.com

Why choose Mycosphere?

✔ Specialized in mushroom cultivation (not a general-purpose electronics lab)
✔ Products tested under real-world growing conditions
✔ French-speaking technical support
✔ Parts and filters available
✔ Customer service based in Belgium
✔ Usage guidelines tailored to mushroom cultivation


Feed Configuration

A versatile model: horizontal or vertical

  • Horizontal airflow: Clean air “sweeps” across the work area from the front—ideal for agar plates, transfers, and precision work.
  • Vertical airflow: clean air flows down onto the work surface—convenient for your ergonomic setup and workflow.
  • Easy setup: Place the PureFlow 600 on a clean table (stable, clean, dust-free surface).

Use of a room under positive pressure

The PureFlow 600 can also be used as a filtered air supply unit to create a slight positive pressure in a small room (principle: more filtered air entering than leaving), which limits the inflow of unfiltered air when the door is opened.

Requirements for good results:

• relatively airtight room
• door slightly open
• flow rate properly adjusted
• appropriate volume

Note: This is not a certified cleanroom, but it is an effective solution for significantly improving the cleanliness of a workspace.


Key strengths

  • HEPA H14 filtration: ≥ 99.995% efficiency at 0.3 µm for extremely clean working air.
  • G4 pre-filter: protects the HEPA filter and helps extend its lifespan.
  • Adjustable airflow: customize the airflow to suit your workspace.
  • Quiet operation and low power consumption: designed for regular use (depending on settings).
  • Low operating costs: easy maintenance and readily available replacement parts.

Technical Specifications

External dimensions 575 × 575 × 320 mm
Main filter HEPA H14
Prefilter G4 Nylon
Pressure Drop Initial ΔP: 200 Pa Final ΔP: ~450 Pa
Airflow 600 m³/h
Airflow speed ~0.45 m/s ± 20% (depending on settings and configuration)
Adjustable speed Yes
Food 220 V – 50 Hz

 

Air Pressure Drop Laminar Flow Hood

Estimated pressure drop curve for the complete system (HEPA filter + prefilter + internal losses). Values are provided for informational purposes only and are based on the filter manufacturer’s data and an estimate of additional system losses.


Maintenance & Replacement Parts

We offer HEPA filters and replacement pre-filters . With regular maintenance, the PureFlow 600 is designed to serve you for years to come.

  • Pre-filter: Check, clean, or replace depending on the level of dust and debris in your environment.
  • HEPA filter: Monitor (airflow, noise, performance) and replace as needed.
Mycosphere Tip: Avoid sources of turbulence (open windows, fans, frequent foot traffic) and keep your workstation clear.

Note: Performance may vary depending on the configuration, the cleanliness of the room, filter maintenance, and operating conditions.


Warranty & Customer Service

The PureFlow 600 is covered by a 12-month warranty from the date of delivery against any manufacturing or component defects under normal use.

  • What the warranty covers: manufacturing defects (chassis/frame), fan/electronics, switch/dimmer (if applicable), wiring, assembly, and abnormal operation caused by a defect.
  • What the warranty does not cover: normal wear and tear, consumables (pre-filter, HEPA filter), clogging, shipping damage not reported within the specified time frame, improper installation, use in an unsuitable environment, or any modifications or repairs performed by a third party.
Important: If there is a defect upon delivery or if you notice any issues, please contact us within 7 days within 30 days of delivery (or upon discovery of the problem) with:
  • the order number,
  • detailed photos (overview + close-ups),
  • and, if possible, a short video showing the issue (noise, flow rate, controls, etc.).

Note: The warranty applies to the product itself (filtration unit/hood). Filters (HEPA and pre-filter) are consumables and are not covered under the warranty due to normal wear and tear. For prompt service, please keep the original packaging and inspect the product upon receipt.


Frequently Asked Questions

Do I need a “clean room” for this to work?

No. The PureFlow 600 creates a zone of filtered air, but the best results are achieved in a clean, quiet, and organized environment.

Does it eliminate 100% of contamination?

No system can guarantee zero contamination. The hood significantly reduces the risk, but technique, hygiene, organization, and the environment remain critical factors.

Customer Reviews

Based on 2 reviews
100%
(2)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
N
Nico N.
No more bills!

I was skeptical at first, but it actually works great and it’s a game-changer. I have a small tent that I use as a lab; I cut a hole in the tent that’s exactly the size of the filter, and it creates positive pressure inside the tent. So now I have a super clean space. Before, I was struggling with the CO2 levels, but since I installed the filter, everything’s been smooth sailing—it’s so much easier! Thanks :)

N
Nico N.
Good Laminar Flow

A sturdy and efficient fume hood. The large size is perfect for our transfer and inoculation procedures. The airflow is consistent, and knowing that replacement filters are available gives us peace of mind for the long term. Since its installation, our results have been more consistent.

Reviews in Other Languages

PureFlow 600 – Laminar flow hood (vertical / horizontal)

PureFlow 600 – Laminar flow hood (vertical / horizontal)
- +

Search