Small Laminar Flow Hood Hepa Filter H14
Small Laminar Flow Hood Hepa Filter H14
Small Laminar Flow Hood Hepa Filter H14
Small Laminar Flow Hood Hepa Filter H14
Small Laminar Flow Hood Hepa Filter H14
Small Laminar Flow Hood Hepa Filter H14

PureFlow 600 – Laminar flow hood (vertical / horizontal)

PureFlow 600 : le flux laminaire compact qui fait la différence.

Créez en quelques minutes une zone d’air ultra-propre pour vos manipulations (agar, transferts, cultures liquides) et dites adieu à une grande partie des contaminations. Posée sur une table propre, utilisable en horizontal ou vertical, et même idéale pour mettre un petit local en surpression : un outil fiable, durable, pensé pour travailler sereinement.

$559.00 Balance
- +

PureFlow 600 Laminar Flow Hood – HEPA H14 – Mycosphere

Choose your size

PureFlow 600 (575 × 575 × 320 mm)

  • Ideal on table, compact stations
  • Agar, transfers, liquid culture
  • Minimal footprint

You are on this page.

PureFlow 1200 (1175 × 575 × 320 mm)

  • Large work area (2 people possible)
  • Perfect for “large volumes” of handling
  • Also very useful for room positive pressure

→ See the PureFlow 1200

The PureFlow 600 is a laminar flow hood designed to create a filtered air zone above your workspace. Its goal is simple: greatly reduce contamination during sensitive handling (agar, transfers, liquid cultures, grains, clones, etc.).

Goal: to work in a filtered and uniform air flow, in order to limit the entry of spores, dust, and particles into your open containers.

Understanding laminar flow

What is a laminar flow hood?

A laminar flow hood draws in air, passes it through a pre-filter then a HEPA H14 filter, and returns clean and uniform air as a steady flow. You thus work “within” a curtain of filtered air that limits the entry of spores, dust, and particles into your open containers.

The HEPA H14 filter retains ≥ 99.995% of particles ≥ 0.3 µm, including fine dust, spores, and biological microparticles.

Good to know: a hood does not replace good practices. For the best results, work in a clean room, protected from drafts, and disinfect your surface (according to your protocols).

Who is the PureFlow 600 for?

✔ Motivated beginners and advanced amateurs
✔ Producers who want a compact and reliable station
✔ Agar, transfers, liquid cultures, inoculations
✔ "On-table" stations / small spaces

Need help choosing?
Our team advises you for free according to your use (agar, liquid culture, volume, room).
→ contact@lamycosphere.com

Why choose Mycosphere?

✔ Specialized in mycoculture (not a general electronics lab)
✔ Products tested under real cultivation conditions
✔ French-speaking technical support
✔ Parts and filters available
✔ After-sales service based in Belgium
✔ Usage tips adapted to fungal cultivation


Flow Configuration

A versatile model: horizontal or vertical

  • Horizontal flow: clean air “sweeps” the work area forward – ideal for agar, transfers, and fine manipulations.
  • Vertical flow: clean air flows down onto the work surface – convenient according to your ergonomics and organization.
  • Simple installation: the PureFlow 600 is placed on a clean table (stable surface, cleaned, dust-free).

Use in room positive pressure

The PureFlow 600 can also be used as a filtered air supply unit to create slight positive pressure in a small room (principle: more filtered air entering than air leaving), which limits the entry of unfiltered air when doors are opened.

Conditions for good results:

• relatively airtight room
• door slightly open
• properly adjusted flow rate
• suitable volume

Note: this is not a certified cleanroom, but an effective solution to greatly improve the cleanliness of a workspace.


Key points

  • HEPA H14 filtration: efficiency of ≥ 99.995% at 0.3 µm for very clean working air.
  • G4 Prefilter: protects the HEPA and helps extend its lifespan.
  • Adjustable airspeed: adapt the flow to your workstation.
  • Quiet operation and controlled consumption: designed for regular use (depending on setting).
  • Controlled operating costs: simple maintenance and available spare parts.

Technical characteristics

External dimensions 575 × 575 × 320 mm
Main filter HEPA H14
Prefilter Nylon G4
Airflow 600 m³/h
Blowing speed ~0.45 m/s ± 20% (depending on setting & configuration)
Adjustable speed Yes
Power Supply 220 V – 50 Hz

Maintenance & spare parts

We offer HEPA filters and replacement prefilters. With regular maintenance, the PureFlow 600 is designed to support you in the long term.

  • Prefilter: to check / clean / replace depending on the contamination level of your environment.
  • HEPA: monitor (flow, noise, performance) and replace when necessary.
Mycosphere Advice: avoid sources of turbulence (open windows, fans, frequent traffic) and keep a clear workstation.

Note: performance may vary depending on configuration, room cleanliness, filter maintenance, and usage conditions.


Warranty & After-Sales Service

The PureFlow 600 is covered by a 12-month warranty from the delivery date, for any manufacturing defect or component defect under normal use.

  • What the warranty covers: manufacturing defects (chassis/frame), fan/electronics, switch/dimmer (if present), wiring, assembly, and abnormal operation related to a defect.
  • What the warranty does not cover: normal wear, consumables (prefilter, HEPA filter), clogging, transport damage not reported within the deadline, improper installation, use in an unsuitable environment, or any modification/repair carried out by a third party.
Important: in case of defect upon receipt or observed problem, please contact us within 7 days following delivery (or following discovery of the problem) with:
  • the order number,
  • detailed photos (general view + close-ups),
  • and if possible a short video showing the problem (noise, flow, control, etc.).

Note: the warranty applies to the product itself (filtration unit/hood). The filters (HEPA and prefilter) are consumables and are not covered under wear and tear. For quick processing, keep the original packaging and inspect the product upon receipt.


Frequently Asked Questions

Do I need a “clean room” for it to work?

No. The PureFlow 600 creates a filtered air zone, but the best results are obtained in a clean, calm, and organized environment.

Does it eliminate 100% of contaminations?

No system guarantees 0 contamination. The hood greatly reduces the risk, but technique, hygiene, organization, and environment remain decisive.

Customer Reviews

Based on 2 reviews
100%
(2)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
N
Nico N.
Fini les contas !

J'avais des doutes au début, mais en fait c'est nickel et ça change la vie. J'ai une petite tente qui me sert de labo, j'ai découpé dans la tente juste la taille du filtre et il met la tente en surpression. Du coup j'ai un espace super clean. Avant je galérais avec les contas et depuis le filtre tout roule, c'est tellement plus facile ! Merci :)

N
Nico N.
Bon Flux Laminaire

Hotte solide et efficace. Le grand format est parfait pour nos séries de transferts et d’inoculations. Le flux est régulier, et le fait d’avoir des filtres de rechange disponibles rassure sur la durée. Depuis l’installation, nos résultats sont plus constants.

Reviews in Other Languages

Customer Reviews

Based on 2 reviews
100%
(2)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
N
Nico N.
Fini les contas !

J'avais des doutes au début, mais en fait c'est nickel et ça change la vie. J'ai une petite tente qui me sert de labo, j'ai découpé dans la tente juste la taille du filtre et il met la tente en surpression. Du coup j'ai un espace super clean. Avant je galérais avec les contas et depuis le filtre tout roule, c'est tellement plus facile ! Merci :)

N
Nico N.
Bon Flux Laminaire

Hotte solide et efficace. Le grand format est parfait pour nos séries de transferts et d’inoculations. Le flux est régulier, et le fait d’avoir des filtres de rechange disponibles rassure sur la durée. Depuis l’installation, nos résultats sont plus constants.

Reviews in Other Languages

PureFlow 600 – Laminar flow hood (vertical / horizontal)

PureFlow 600 – Laminar flow hood (vertical / horizontal)
- +

Perform a search